ECO-dura—— Long Life Electrochemical CO Sensor
Features
² More than 10 years lifetime
² Battery operable
² High selectivity to carbon monoxide
² Good linearity and repeatability
² No direction limit
² Meet EN50291, UL2034, GB15322.5, etc
Operating performance
Item | Specification |
Operating Principle | 2-electrode electrochemical cell |
Measurement Rang | 0-2000 ppm |
Output Signal | 1.0~2.6 nA/ppm |
Precision | 1 ppm |
Operating Temperature Range | -20~+40 ℃ |
Storage Conditions | -20~+60 ℃ |
Humidity Range | 5%~95%RH |
Response Time | <60 S |
Resume Time | <60 S |
Expected Operating Life | >12 Years |
Standard Test Conditions | 20±2℃ 40±10%RH |
Performance Data:
1. Temperature Dependency
The following figure illustrates the typical effect of temperature on the output signal of the ECO-dura .The sensor was calibrated at 20 ℃ and 40%RH (Io).

3. Humidity Dependency
The following figure illustrates the typical effect of humidity on the output signal of the ECO-dura .The sensor was calibrated at 20 ℃ and 40%Rh.

3. High Concentration CO overload
In EN50291, the sensor must be endured 5000 ppm CO impact and must be recoverd in 1 hour by itself. The following graph shows good performance of ECO-dura sensors.